QUALITY CONTROL

Tested before shipment is non-negotiable

Three-stage QC — incoming material, in-line inspection, pre-shipment full-batch testing. Every shipment carries a PDF test report tied to a traceable batch number.

The eight checks every order goes through

From raw material on the shelf to the carton on the truck. None of these get skipped for rush orders.

  • Incoming material

    Every batch of raw fiber, connectors, and ceramic ferrules is sampled on arrival. We keep one consistent supplier per material category so batch-to-batch behavior stays predictable.

  • Connector end-face

    Every connector inspected at 200× magnification for surface defects and contamination. APC connectors verified at the 8° angle tolerance via interferometer.

  • IL / RL test

    Every patch cord goes through insertion-loss and return-loss testing on a calibrated source-meter pair. Pass thresholds: IL ≤ 0.3 dB SMF UPC, RL ≥ 60 dB APC.

  • Length & polarity

    MPO/MTP polarity (Type A/B/C) verified on a polarity checker. Length tolerance ±5 cm for ≤ 10 m, ±0.5 % above 10 m.

  • Compatibility coding

    Every batch of compatible SFP/SFP+/QSFP transceivers bench-tested on the target switch family (Cisco, Juniper, Arista, Nvidia/Mellanox, HPE Aruba) for link-up and DOM stability.

  • Packaging audit

    Bag sealing, anti-static wrap, carton layout, desiccant placement, and label/barcode positioning are all checked before the carton is sealed.

  • Pre-shipment report

    Every shipment carries a digital PDF test report — IL/RL per cord, compatibility log per transceiver, polarity per MPO — with batch traceability.

  • After-sales traceability

    90-day return-replace policy; every reported failure logged to the batch traceability system so root cause is investigated without finger-pointing.

IN-HOUSE LAB

Eight specialized test stations

Reliability, dimensional accuracy, environmental endurance, regulatory compliance — tested in-house, not subcontracted.

ISO 9001 quality systemIEC 61300 series
  • End-face geometry

    End-face geometry

    Apex offset, fiber height, radius of curvature — within IEC 61755-3 limits for every polished connector.

  • Dimensional inspection

    Dimensional inspection

    Coordinate-measuring of ferrule OD, eccentricity, and ferrule-to-housing concentricity on every connector lot.

  • Pulling-force test

    Pulling-force test

    Horizontal pull test on assembled cables to verify minimum tensile strength per IEC 60794-1.

  • Vibration test

    Vibration test

    Random-vibration profile applied to packaged transceivers and cabled connectors to validate transport durability.

  • Temperature / humidity cycling

    Temperature / humidity cycling

    Programmable temp-humidity chamber: −40 °C to +85 °C cycles, ≥ 95 % RH soak — IL/RL drift checked at each setpoint.

  • Flammability (UL VW-1)

    Flammability (UL VW-1)

    Horizontal and vertical flame test on PVC and LSZH jackets to confirm self-extinguishing behavior.

  • Salt-spray corrosion

    Salt-spray corrosion

    Connector metalwork exposed to 5 % NaCl mist per ASTM B117 to certify coastal / marine deployment readiness.

  • RoHS / REACH compliance

    RoHS / REACH compliance

    Material declarations verified per batch; X-ray fluorescence (XRF) on connector metals for heavy-metal limits.

Cabling under inspection

TRACEABILITY

One serial → one test record → one raw-material lot

Every cable serial we ship maps to a test record, which maps to a raw-material lot. When a unit fails on installation, we can pull the lot and check whether other units from the same batch share a defect pattern — without finger-pointing.

  • PDF test report attached to every export shipment.
  • 90-day return-replace with one-page incident form.
  • Batch-recall capability for material-level defects.

Need a redacted sample test report?

Email us — we can send a sample for any product category before you commit.